Inter- and intra-examiner reliability of the strength of shoulder rotators in different positions using isometric dynamometry

Authors

  • Michele Forgiarini Saccol Universidade Federal de Santa Maria; Departamento de Fisioterapia
  • Gislaine dos Santos Universidade Federal do Pampa (Unipampa) - Uruguaiana (RS), Brasil
  • Henrique Jardim Oliano Universidade Federal do Pampa

DOI:

https://doi.org/10.1590/1809-2950/17257624042017

Keywords:

Muscle Strength Dynamometer, Shoulder, Reproducibility of Results, Muscle Strength

Abstract

The handheld dynamometer is a portable device of easy use in clinical practice. However, its use requires reliability and reproducibility parameters in shoulder positions with and without stabilization. The objective of this study was to evaluate the inter- and intra-examiner reliability of the shoulder rotator strength measurement at 0° and 90° abduction with inexperienced examiners. Twenty subjects (27.05 ± 8.17 years, 76.6 ± 10.97 kg, 1.74 ± 0.07 m) of both sexes and no previous or current complaints of shoulder and neck pain participated in this study. The evaluation of the internal and external shoulder rotators was performed using a handheld dynamometer (MicroFET 2, Hoogan Health Industries, West Jordan, UT, USA) in two positions: sitting with 0° shoulder abduction and supine and with 90° shoulder abduction. Inter- and intra-examiner reliability and reproducibility were assessed through the intraclass correlation coefficient (ICC) considering a 95% confidence interval (p<0.05). There was excellent reproducibility in the intra-examiner analysis and very good levels of reliability measures in the inter-examiner analysis for most variables. The positions of 0° and 90° shoulder abduction showed reliable and reproducible results when using the handheld dynamometer with examiners that had no clinical experience.

Downloads

Download data is not yet available.

References

Hudson VJ. Evaluation, diagnosis, and treatment of shoulder

injuries in athletes. Clin Sports Med. 2010;29(1):19-32. doi:

1016/j.csm.2009.09.003

Mendonça LDM, Bittencourt NFN, Anjos, MTS, Silva AA,

Fonseca ST. Avaliação muscular isocinética da articulação

do ombro em atletas da Seleção Brasileira de voleibol sub-19

e sub-21 masculino. Rev Bras Med Esporte. 2010;16(2):107-11.

doi: 10.1590/S1517-86922010000200006

Metzker C. Tratamento conservador na síndrome do impacto

no ombro. Fisioter Mov. 2010;23(1):141-51. doi: 10.1590/

S0103-515020100000100014

Riemann BL, Davies GJ, Ludwig L, Gardenhour H. Handheld dynamometer testing of the internal and external

rotator musculature based on selected positions to establish

normative data and unilateral ratios. J Shoulder Elbow Surg.

;19(8):1175-83. doi: 10.1016/j.jse.2010.05.021

Edouard P, Degache F, Beguin L, Samozino P, Gresta G,

Fayolle-Minon I, et al. Rotator cuff strength in recurrent

anterior shoulder instability. J Bone Joint Surg Am.

;93(8):759-65. doi: 10.2106/JBJS.I.01791

Schrama PP, Stenneberg MS, Lucas C, van Trijffel E.

Intraexaminer reliability of hand-held dynamometry in the

upper extremity: a systematic review. Arch Phys Med Rehabil.

;95(12):2444-69. doi: 10.1016/j.apmr.2014.05.019

Hayes K, Walton JR, Szomor ZL, Murrell GA. Reliability of 3

methods for assessing shoulder strength. J Shoulder Elbow

Surg. 2002;11(1):33-9. doi: 10.1067/mse.2002.119852

Schwartz S, Cohen ME, Herbison GJ, Shah A. Relationship

between two measures of upper extremity strength: manual

muscle test compared to hand-held myometry. Arch Phys

Med Rehabil. 1992;73(11):1063-8.

Cools AM, Johansson FR, Cambier DC, Velde AV, Palmans T,

Witvrouw EE. Descriptive profile of scapulothoracic position,

strength and flexibility variables in adolescent elite tennis

players. Br J Sports Med. 2010;44(9):678-84. doi: 10.1136/

bjsm.2009.070128

Hurd WJ, Morrey BF, Kaufman KR. The effects of

anthropometric scaling parameters on normalized muscle

strength in uninjured baseball pitchers. J Sport Rehabil.

;20(3):311-20. doi: 10.1123/jsr.20.3

Turner N, Ferguson K, Mobley BW, Riemann B, Davies

G. Establishing normative data on scapulothoracic

musculature using handheld dynamometry. J

Sport Rehabil. 2009;18(4):502-20. doi: 10.1249/01.

mss.0000355361.92965.94

Andrews AW, Thomas MW, Bohannon RW. Normative values

for isometric muscle force measurements obtained with

hand-held dynamometers. Phys Ther. 1996;76(3):248-59.

Beshay N, Lam PH, Murrell GA. Assessing the reliability

of shoulder strength measurement hand-held versus

fixed dynamometry. Shoulder Elbow. 2011;3:244-51. doi:

1111/j.1758-5740.2011.00137.x

Cools AM, De Wilde L, Van Tongel A, Ceyssens C, Ryckewaert

R, Cambier DC. Measuring shoulder external and internal

rotation strength and range of motion: comprehensive

intra-rater and inter-rater reliability study of several testing protocols. J Shoulder Elbow Surg. 2014;23(10):1454-61. doi:

1016/j.jse.2014.01.006

Donatelli R, Ellenbecker TS, Ekedahl SR, Wilkes JS,

Kocher K, Adam J. Assessment of shoulder strength in

professional baseball pitchers. J Orthop Sports Phys Ther.

;30(9):544-51. doi: 10.2519/jospt.2000.30.9.544

Leggin BG, Neuman RM, Iannotti JP, Williams GR, Thompson

EC. Intrarater and interrater reliability of three isometric

dynamometers in assessing shoulder strength. J Shoulder

Elbow Surg. 1996;5(1):18-24.

Weir JP. Quantifying test-retest reliability using the intraclass

correlation coefficient and the SEM. J Strength Cond Res.

;19(1):231-40. doi: 10.1519/15184.1

Wilk KE, Yenchak AJ, Arrigo CA, Andrews JR. The Advanced

Throwers Ten Exercise Program: a new exercise series

for enhanced dynamic shoulder control in the overhead

throwing athlete. Phys Sportsmed. 2011;39(4):90-7. doi:

3810/psm.2011.11.1943

Rathbun JB, Macnab I. The microvascular pattern of the

rotator cuff. J Bone Joint Surg Br. 1970;52(3):540-53.

Reinold MM, Wilk KE, Fleisig GS, Zheng N, Barrentine

SW, Chmielewski T, et al. Electromyographic analysis of

the rotator cuff and deltoid musculature during common

shoulder external rotation exercises. J Orthop Sports Phys

Ther. 2004;34(7):385-94. doi: 10.2519/jospt.2004.34.7.385

Kuechle DK, Newman SR, Itoi E, Niebur GL, Morrey BF, An

KN. The relevance of the moment arm of shoulder muscles

with respect to axial rotation of the glenohumeral joint in

four positions. Clin Biomech. 2000;15(5):322-9. doi: 10.1016/

S0268-0033(99)00081-9

Fransen M, Crosbie J, Edmonds J. Isometric muscle

force measurement for clinicians treating patients with

osteoarthritis of the knee. Arthritis Rheum. 2003;49(1):29-35.

doi: 10.1002/art.10923

Wikholm JB, Bohannon RW. Hand-held Dynamometer

Measurements: Tester Strength Makes a Difference. J

Orthop Sports Phys Ther. 1991;13(4):191-8. doi: 10.2519/

jospt.1991.13.4.191

Bohannon RW, Andrews AW. Interrater reliability of handheld dynamometry. Phys Ther. 1987;67(6):931-3.

Kelln BM, McKeon PO, Gontkof LM, Hertel J. Hand-held

dynamometry: reliability of lower extremity muscle testing

in healthy, physically active,young adults. J Sport Rehabil.

;17(2):160-70.

Published

2017-12-12

Issue

Section

Original Research

How to Cite

Inter- and intra-examiner reliability of the strength of shoulder rotators in different positions using isometric dynamometry. (2017). Fisioterapia E Pesquisa, 24(4), 406-411. https://doi.org/10.1590/1809-2950/17257624042017